Keyence XM-1200 Handheld Probe CMM with XM-1500 Controller, new 2017
To the best of our knowledge all details listed below are deemed correct.
It is the buyer’s responsibility to confirm all details and we encourage an inspection of the machine(s) and accessories prior to purchase.
General Specifications:
Camera Image Pickup Device: 4 MP CMOS Image Sensor
Camera Wavelength at Light Receiving Center: Near-Infrared
Measuring Range: 23.62" x 11.81" x 7.87"
Display Unit Distance: 1 uM
Angle: 0.0001 Degrees
Measurement Repeatability: Stage Locked: +3uM / Stage Unlocked: +4 uM
Measurement Indication Error: Stage Locked: +8uM / Stage Unlocked: + (10 + L/100) uM
Stage Withstand Load: 55 lbs
X-Axis Movable Range: +3.94"
Stage Rotation Range: +60 Degrees
Number of Probes: 1
Number of Stage Markers: 6
Probe Connection Port: 2 Inputs
Interfaces: USB 2.0 / 3 Ports
Display: 15" LCD Monitor
XM-1500 Controller Specifications:
HDD: 320 GB
Communication: RS-232C / USB 2.0 - 6 Ports / LAN RJ45
External Output: DVI-D
Measuring Mode: Program Mode/Rub Mode/Statistics Analysis/Single Measurement
Number of Configurable Elements: 500 (Excluding Comment Elements)
Measurement Points: 200 Points Per Element
Measurement Between Elements: Distance / Angle / Calculation
Basic Elements: Plane/Line/Point/Circle/Cylinder/Cone/Sphere
Particular Measurement Element: Point - No Correction/Ellipse/Single Point Circle/Stepped Cylinder/Oval/Round Slot/Corner Arc/Chamfer Line/Torus
Virtual Figures
Point: Midpoint/Contact point/Intersection/Perpendicular/Numerical input/Element specification
Line: Median line/Tangent line/Intersect line/Projection line/Rotation line/Numerical input/Element specification
Plane: Median plane/Parallel plane/Numerical input/Element specification
Circle: Intersect circle/Numerical input/Element specification
GD&T
Form: Flatness/Roundness/Straightness/Cylindricity
Orientation: Parallelism/Perpendicularity/Angularity
Location: Position/Concentricity/Coaxiality/Symmetry
Coordination
New: Simple coordinate/Type A coordinate/Type B coordinate/Specified coordinate
Change: Base plane settings/Fit axis to point/Fit axis to line/Rotate axis/Fix axis to offset point/Set origin/Reset coordinate
Work Adjust: Work Adjust
Apps
Distance: Plane-to-point height/Plane-to-plane distance/Hole position
Angle: Dihedral angle/Edge to edge angle
Diameter: Diameter/Pitch circle diameter/Lower diameter/Upper diameter
Position: Hole position/V groove
Batch Settings: Batch tolerance settings/Batch settings for output/display Items/Guidance image batch settings/List edit
Number of Measurement Macro Settings: 100
Number of Probe Settings: 10
Average Times Of Measurement: 1/2/4/8/16
We use cookies to improve your experience. Privacy Policy.